Periprosthetic plate synthes
WebA limited-contact design reduces plate-to-bone contact and helps to preserve the periosteal blood supply. Early mobilization Plate features combined with AO technique create an envi-ronment for bone healing, expediting return to function. 4 Synthes LCP Proximal Femoral Hook Plate 4.5/5.0 Technique Guide WebPeriprosthetic fractures (PPFs) present unique challenges to orthopaedic surgeons in terms of limited cortical fixation options, poor bone quality, cement mantles, and stress risers introduced from the prosthesis. Various fixation strategies have been used in PPFs including the use of intramedullary nails, locked plates, unicortical locking ...
Periprosthetic plate synthes
Did you know?
WebAlthough treatment through revision TKA has been described, this treatment modality is limited in the setting of an interprosthetic fracture. 1 Here, the nail plate combination (NPC) technique 2 was applied to treat the interprosthetic fracture, whereas locked plating was used to treat the periprosthetic tibia fracture; below, a case-based … WebApr 1, 2024 · Currently, anatomical plates are being used in dedicated centres for clavicle, acetabulum, talus, calcaneum and ‘Hook’ plates for periprosthetic fractures of proximal femur. Apart from these, plates with cable anchorage have come into use for periprosthetic fractures . For femoral neck fractures, we now have anatomic implants which have a ...
WebOur plating portfolio ranges from indication specific plates and patented Smartlock technology to streamlined instrumentation for ease-of-use in the OR. Solving complicated fractures with simple innovative solutions – Plating that fits. Fit for patients Fit for procedures Fit for you Fit for the future Contact Related categories Orthopaedics WebThe Synthes 5.0 mm Periprosthetic Locking Screws are intended for fixation of various long bones, such as the humerus, femur and tibia, in conjunction with Synthes locking …
WebPeriprosthetic fractures (PPFs) present unique challenges to orthopaedic surgeons in terms of limited cortical fixation options, poor bone quality, cement mantles, and stress risers …
WebThe Synthes LCP Distal Femur Plates are intended for buttressing multifragmentary distal femur fractures including: supracondylar, intra-articular and extra-articular condylar, periprosthetic fractures; fractures in normal or osteopenic bone; nonunions and malunions; and osteotomies of the femur. LCP Distal Femur Plates
WebFeb 8, 2024 · This study compared the distal lateral femur plate (LOQTEQ®, aap Implantate AG) with a standard L.I.S.S. LCP® (DePuy Synthes) regarding their biomechanical properties in fixation of ... boy nursery decorationsWebNational Center for Biotechnology Information gwb205 bassWebCannulated Screw System CSS CONDUIT™ Lumbar Cages─Part of the CONDUIT™ Interbody Platform UNIUM™ Small Bone and Trauma Power Tool The new VA-LCP … boy nursery crib bedding setsWebFemur compression bone plate / periprosthetic fracture Depuy Synthes Depuy Synthes. Click. for Price / Quote. Click for Documentation. Click for Questions. Description Specifications Contact This locking attachment plate can be used as a less-invasive alternative to ceclarge when it comes to periprosthetic femoral fractures. With its … boy nursery ideas woodlandWebApr 4, 2024 · Fractures around joint replacement prostheses are commonly called periprosthetic fractures, whereas fractures around plates, rods, or prostheses can be more generally termed peri-implant fractures. … gwb35 bassWebJun 28, 2024 · The front plate acts as a lens and is provided in aphakic version compatible with a variety of axial lengths (16.0 mm to 31.00mm) or in pseudophakic version when an … boy nursery design ideasWebAlthough treatment through revision TKA has been described, this treatment modality is limited in the setting of an interprosthetic fracture. 1 Here, the nail plate combination … gwb8-e gas-fired water boiler